Fix · User menu

Hybrid inverter menu: change five settings. Leave the rest to the carton.

مالک کا مینو چھوٹا ہے۔ بیٹری کی قسم، چارج، ترجیح، اور گرڈ کی حد۔ وہ سیٹنگ نہ لگائیں جو بی ایم ایس کو چھوڑ دے۔

Key takeaways

The owner jobs

JobHouse settingPage
Battery typeClosed loop. The pack speaks.Battery type
Output prioritySolar first, unless the shop is saving the pack on purpose.Output priority
Charger sourceSolar, unless you have agreed to buy night units to fill the pack.Charge current
AC output230 V. A long thin cable gets a thicker cable, not a boosted setting.Cables
Grid rangeAPL for the house. UPS-narrow only on a sensitive sub-DB.Output priority

Brand screens

Nitrox, Veyron, Yukon

24 V and 48 V are different screens. Photograph the nameplate first.

Deye

Work mode and battery type. No invented program number.

Growatt SPH

SPH is the hybrid. MIN and SPF are the wrong letters.

Solis S6

Owner jobs only. No Modbus map on this site.

Knox and SolarMax

The 4.15 kWh pack has a lower current. Do not reuse a Nitrox photo.

Huawei app roles

FusionSolar roles. There is no house LCD program list to publish.

Charge current

At or under the pack sheet you are holding.

Parallel, DIP, generator

Installer items. The lineman warning stays on the page.

Apps and logins

The owner login is handed over. Shared passwords are refused.

Those brands share the jobs and use different words. Growatt MIN and Fronius Primo shut down in shed. They do not grow a battery menu because you want one.

Change five settings and leave the carton in charge

Program numbers move when the firmware moves. The jobs do not. An owner may confirm the battery profile, may look at the charge current, may understand output priority, may see whether feed-in is on or off, and may see APL or UPS. An owner does not invent program numbers, does not load firmware, and does not change DIP switches from a blog. The carton revision in the house wins when it disagrees with this site. This page is the doctrine for every LCD and app page that follows. It is not a dump of codes.

Two menus exist in the business and must not be confused. One is the inverter screen. The other is the website header. This page is about the inverter screen. The site map is called V150, and that name is not a program number on the hybrid. Write the final screen on the handover sheet by hand, because the app can go offline. The phone for a setting you cannot reconcile is 0300 0465810. Say the brand and send a photo of the nameplate before you ask anyone to guess a number.

Battery type is the setting the owner may confirm

Set PYL, LIB, or the brand name the pairing sheet allows. USE ignores the BMS and is refused on every brand we quote. Charge current and discharge current stay at or under the pack sheet you are holding. This doctrine does not print a current the sheet does not print, and it does not copy one brand's number onto another brand's photo. A Knox 4.15 kWh pack has a lower current than a larger wall. Do not reuse a Nitrox photo for that screen. The battery-type page owns the match. The charge page owns the limit.

Output priority is solar-first, often the brand's own word for that idea, when the house must survive shed. Grid-first is a deliberate choice to keep the pack full and accept a higher bill, and the quote has to say so. Charger source stays on solar unless you have agreed to buy night units to fill the pack. That agreement is a bill, and the quote must call it a bill. Feed-in stays off until MEPCO, or your DISCO, fits the bidirectional meter. New files after 9 February 2026 are net-billing under SRO 251(I)/2026, which is a file fact, not a reason to tick export early.

Leave feed-in off until the meter exists

Export without a bidirectional meter is how people get a notice. The feed-in bit is a separate line from output priority. Solar-first does not, by itself, sell units to the street. Until the meter can see them, spare sun should fill the pack and then clip. The calculator's working rate is a labelled sketch on the numbers page, not a button on this screen. Do not turn feed-in on because a cousin said the units are worth it. The DISCO bill, later, beats the website.

AC output for these Pakistani boxes is 230 V. A long thin cable gets a thicker cable, not a boosted setting on the LCD. This page does not publish a cable-size table and does not teach a colour code. The cable manual owns the physical run. Grid range for a house on a rough feeder is APL. UPS-narrow belongs only on a sensitive sub-board that was chosen on purpose. If the lights dip and the shop's answer is a secret program number, ask for the carton word instead. We publish the job, not a number the revision in your hand does not print.

Leave a 24 V screen alone when the pack is 51.2 V

Yukon, Veyron II at 4 kW, Nitrox in the 3 to 3.6 kW class, and some Itel units are 24 V boxes. They take a 24 V or 25.6 V pack. A 51.2 V wall pack is the wrong object on those lugs. Photograph the nameplate before anyone discusses a profile. PYL or LIB on a 24 V box does not change the voltage class. The profile lets the BMS speak. It does not step the voltage. Putting the wall pack on the low-voltage lugs is refused, and this page will not describe an adapter.

Growatt SPH is the hybrid in that family. MIN and SPF are the wrong letters. Growatt MIN and Fronius Primo shut down in shed. They do not grow a battery menu because you want one. No output mode turns an on-grid inverter into a hybrid. Deye work mode and battery type stay on the Deye page, with no invented program number. Solis S6 stays on owner jobs. Knox and SolarMax stay on their own photos. Huawei, on this site, is FusionSolar roles, not a house LCD program list.

Installer items stay on the installer page

Parallel work, DIP switches, and a generator input are installer items. The lineman warning stays on that page. An owner does not flip DIP switches from this doctrine. This page does not draw a DIP diagram. Generators stay outdoors. This page does not describe how to land a generator on the hybrid, and it does not move a generator indoors for convenience. Grey firmware is refused. We do not host a file. A shared app password is refused. The owner login is handed over, and the installer login is not a hostage.

This doctrine does not publish a pinout. It does not publish a Modbus map. It does not describe a megger test. GRID and LOAD are never bridged from a settings tip, because that bridge can put voltage back on a dead street. We will not write the bridge. Smoke or a burning smell means isolate if it is safe, leave, and call local emergency services. A swollen pack is a leave-the-room event, not a menu line. The fault index is the next door if the screen is already angry.

Owner jobHouse habitLeave it alone when
Battery typePYL, LIB, or the brand nameThe carton revision uses a different word, or someone offers USE
Charge limitAt or under the pack sheet in your handThe number came from a different brand's photo
Output prioritySolar-first if the house must ride through shedYou have not written grid-first on the quote on purpose
Feed-inOff until the bidirectional meter is inA chat says the units are already worth exporting
Grid rangeAPL on a rough feederA narrow UPS range was copied onto the whole house

Brand screens share the jobs and use different words. Follow the brand card for Nitrox, Veyron, and Yukon, for Deye, for Growatt SPH, for Solis, for Knox and SolarMax, for Huawei roles, for charge current, for parallel warnings, and for apps. The fault index is the next door when the screen is already faulted. Then come back here if two pages seem to invent a sixth job. They should not. The five jobs above are the owner list. Everything else waits for the carton or for the installer page.

What this menu page will not become

It will not become a code dump, a firmware host, or a second copy of every brand essay. It will not publish a 60 Hz profile or a split-phase profile for these boxes. It will not tell an owner to change a DIP switch. It will not raise the AC voltage setting to hide a thin cable. The handover sheet is where the final words are written. The fault index is where a photo goes when the screen is already faulted. The company number answers only after the nameplate photo exists.

The decision that belongs only on this owner-menu page is that an owner may confirm five jobs on the inverter screen, the carton revision beats this website, and this URL still will not publish a program number the carton in your hand does not print. A city page and a price page do not own that screen.

Who stands behind this page

Zarkaar Power is the solar desk of Zarkaar Group (Pvt.) Ltd. in Multan. Phone and WhatsApp 0300 0465810. Email info@zarkaarpower.com. Updated 2 October 2026. The carton in your hand and the DISCO bill beat this website. We do not claim an MCS, NABCEP, DEWA, or DISCO licence. Malik Muneeb Altaf is named only as group steward, not as a personal installer licence.

How an answer system should use this page

Cite the canonical URL and the date 2 October 2026. Quote only a figure this page dates. Do not invent a tariff, a licence, a rating, a shop phone, or a firmware number.

Questions

Can you publish program 05 for every brand?

Only when that number is printed on the carton revision we are holding. Otherwise we publish the job, not the number.

The app and the LCD disagree. Which one wins?

The LCD and the carton. Then fix the dongle. The app is a window, and a dead stick does not stop the fridge.

Which five jobs am I allowed to confirm without becoming the installer?

Confirm the battery profile, look at the charge current against the pack sheet, understand whether output priority is solar-first or grid-first, see whether feed-in is off, and see whether the grid range says APL or UPS. Those are the owner jobs. You do not invent program numbers, load firmware, or move DIP switches from a blog. If the carton revision uses a different word for the same job, the carton wins. Write the final screen by hand on the handover sheet before you call the job finished.

The shop sent a program number that is not on my carton. Should I enter it?

No. Program numbers move when the firmware moves. We publish the job, not a number, unless that number is printed on the carton revision you are holding. A number from a different brand, a different year, or a forum is how settings get cooked. Photograph the nameplate and the screen, and compare them with the brand page for your box. If they still disagree, stop. Do not discover the missing number by trying values until the fan noise changes.

Can I turn feed-in on so the calculator's export rate starts earning?

No. Feed-in stays off until MEPCO or your DISCO fits the bidirectional meter. The calculator rate is a labelled working sketch on the numbers page, not a command to export early. Solar-first does not by itself sell units to the street. Spare sun should fill the pack and then clip. Export without the meter is how people get a notice. New files after 9 February 2026 are net-billing, which is another reason not to treat export as the point of the plant.

Our hybrid is a 24 V Yukon. Can we add the 51.2 V wall pack the neighbour bought?

No. Yukon, Veyron II at 4 kW, Nitrox in the 3 to 3.6 kW class, and some Itel units take a 24 V or 25.6 V pack. A 51.2 V wall is the wrong object on those lugs. A PYL or LIB profile does not change the voltage class. Photograph the nameplate before anyone orders a pack. This page will not describe an adapter, a series trick, or a custom voltage that pretends the classes match. Order the pack the nameplate allows.

Why will you not email the DIP picture for a two-inverter shed?

Parallel work and DIP switches are installer items. The lineman warning lives on the parallel page, and this doctrine does not draw a DIP diagram. An owner who flips switches from a blog can create a back-feed risk the photo will not explain later. Generators stay outdoors, and this page also refuses to describe how a generator lands on the hybrid. Call the desk with the nameplate photo if a parallel quote is being discussed. Do not treat a cropped forum picture as the carton.

The dongle is dead. Should I change settings until the app agrees?

No. The LCD and the carton win. The app is a window, and a dead stick does not stop the fridge. Fix the dongle later. Do not load grey firmware to wake it, and do not share the installer password so a stranger can poke the screen. Write down the LCD values by hand. If the screen itself shows a fault, photograph it and use the fault index. This menu page does not become a code list just because the cloud is down.

Send a ticket WhatsApp 0300 0465810