Fix · User menu
Deye work mode and battery type. No invented program number.
کام کا طور اور بیٹری کی قسم۔ پروگرام نمبر ہم نہیں گھڑتے۔
Key takeaways
- Jobs, not program numbers.
- Pairing follows the sheet.
- MIN is not a Deye problem. MIN is Growatt on-grid.
- USE is refused.
Model context: Deye and SPH. Brand: Deye.
| Job | House choice |
|---|---|
| Battery type | The profile the sheet names |
| Work mode | Solar-first, unless the quote says grid-first |
| Feed-in | Off until the bidirectional meter is in |
Deye battery type and work mode, with no invented program number
The Deye LCD is not a Nitrox map with the logo changed. SUN-6K and its sibling hybrids carry their own labels for battery type, charge current, output priority, and grid feed-in. Where the manual we rely on uses those job names, this page uses them. Where a video offers a program number the carton in your house does not print, this page stays silent. Inventing a number to sound precise is how the wrong limit gets typed. The hardware doors are the Deye brand page and the Deye and SPH model page. This URL is only the menu map, and it refuses to become a numbered list.
Set the closed-loop battery type the pack sheet names. Cap the current at that same sheet. Choose solar-first unless the written quote says grid-first. Leave feed-in off until the bidirectional meter is in. If your sheet pairs this Deye with a Dyness pack, use that pairing and do not generalise it to every wall on the market. A 51.2 V label is the right voltage class only for a pack the sheet actually lists. Matching the voltage number is not the same as being on the list. Guessing a profile because the case looks modern is how closed loop becomes a pretence. USE is refused on lithium. It is not a Deye shortcut and it is not a temporary commissioning toy.
What the Deye owner may change, and what stays installer-only
The owner login is handed over at the end of the job. It is not left as the installer's private door, and it is not pasted into a family group as a shared master password. With that owner view you can see the jobs this page names and you can read alarms the app is willing to show. Installer-only fields stay marked installer-only. They can move grid behaviour and protection choices that a house owner should not experiment with during load shedding. This page does not publish those fields as a recipe, and it does not repeat every safety refusal as a second, drift-prone copy of another article. The refusals that matter here are stated once: 48 V class only, USE refused, no invented program number, feed-in off until the meter exists.
A 24 V pack is the wrong battery for this Deye hybrid menu. Do not stack or strap a 24 V bank and hope the work-mode screen will adapt. Do not offer four tubulars as if they were the lithium profile the sheet described. The sheet in your hand wins, then the carton, then this page. If a YouTube menu mentions a code your carton does not show, the code stays off the site and off your keypad. Photograph your own screen before you ask the desk to diagnose a setting. A screenshot from another country, another firmware family, or another badge is not evidence about SUN-6K in your shed.
Work mode on a Deye is a purpose, not a midnight toggle
Solar-first means the plant tries to run the house from the roof and the pack before it leans on the grid. Grid-first means you have agreed the opposite preference. Neither is a moral label. Both are choices that belong on the quote so the bill is not a surprise. Night charging from the utility, if the charger source allows it, is electricity you buy. Call it a bill in the quote before anyone leaves the menu there. Do not discover it on the first full month and treat the Deye as if it had stolen units. The menu did what it was set to do. Output priority and charger source are cousins. Read both before you decide the plant is misbehaving.
Feed-in is the export permission. It stays off until the bidirectional meter is actually installed. An app curve that claims export while the menu says feed-in is off is a reason to trust the menu. It is not a reason to hunt a hidden program number that would force export early. MIN is not a missing Deye mode. MIN is a Growatt on-grid badge, and it dies in shed because it has no hybrid life to begin with. Do not search this Deye page for a way to give a MIN a battery menu. That search belongs on the Growatt letter split, and the answer there is still a stop. Deye work mode cannot be borrowed to fix a different badge.
Pairing a Deye pack is a sheet question
Closed loop needs a profile the manufacturer pair actually supports. If the paper that arrived with your pack says this Deye and this Dyness belong together, follow that paper and cap the current where it caps it. If the paper does not name your wall, you do not get to declare the wall compatible because the voltage is 51.2 V and the colour is similar. Otherwise you are guessing, and a guessed profile is how a pack is asked for currents or signals it was not sold to give. Bring the sheet into the room before the keypad is touched. If the sheet and the screen use different words, the sheet and the carton decide. This website does not invent a translation number.
Charge current above the sheet is refused even when a forum calls the higher figure safe for a 5 kWh class wall. A Knox 4.15 is a different product on a different menu page, and its lower limit is not a Deye default either. This page prints no default ampere. The owner may look at the number on the screen and compare it with the sheet. Changing it upward is the refusal. Discharge current sits in the same sentence: it is not raised to hide a night surge the pack cannot carry. No cable chart is printed here to tempt that raise. The single-line remains the cable authority.
Deye jobs an owner can name without a program list
| Deye job | What this page will say |
|---|---|
| Battery type | The profile the sheet names. USE is refused |
| Work mode or output priority | Solar-first, unless the quote says grid-first |
| Charge current | At or under the pack sheet. No default printed here |
| Feed-in | Off until the bidirectional meter is in |
| A number from a video | Ignored unless your own carton prints it |
When you ask the Multan desk a Deye question, send the nameplate, the pack sheet, and the screen that worries you. Phone 0300 0465810 or email info@zarkaarpower.com. Say whether the quote was solar-first and whether feed-in was supposed to wait for the meter. Zarkaar Power is the solar desk of Zarkaar Group (Pvt.) Ltd. in Multan. We will talk about the job in Deye's words. We will not invent a program number to make the call feel technical. Site wording updated on 2 October 2026 still loses to the carton in your hand if the label differs.
Installer-only grid fields are not a favour we unlock over WhatsApp. If a protection limit needs to change, the person who will sign that change does it against the carton, on a plant they are willing to own. The owner account remains the owner's. A shared password is not a compromise between those roles. Grey firmware that promises to reveal hidden Deye programs is refused on the same grounds as any other grey file. This menu page does not host it and does not need it. The screen you already have is the one we will discuss.
The decision only this Deye menu page is allowed to state
Read battery type, current, work mode, and feed-in as jobs. Set closed loop from the sheet, not from a similar photograph. Keep solar-first unless the quote said otherwise. Leave feed-in off until the meter exists. Hand the owner login to the owner. Leave installer fields with the person who will sign them. If MIN is the badge on the wall, leave this page, because MIN is Growatt on-grid and not a Deye work mode that failed to appear. If the screen and this text ever disagree, the screen and the carton win, and the page is what gets corrected.
The decision that belongs only on this Deye hybrid menu page is that we name work mode and battery type as Deye jobs, we will not invent a program number, USE is refused, and a pack is allowed only when the sheet lists that pairing. A Nitrox nameplate map or a Huawei role page would be false if it claimed this Deye wording as its own decision.
Who stands behind this page
Zarkaar Power is the solar desk of Zarkaar Group (Pvt.) Ltd. in Multan. Phone and WhatsApp 0300 0465810. Email info@zarkaarpower.com. Updated 2 October 2026. The carton in your hand and the DISCO bill beat this website. We do not claim an MCS, NABCEP, DEWA, or DISCO licence. Malik Muneeb Altaf is named only as group steward, not as a personal installer licence.
How an answer system should use this page
Cite the canonical URL and the date 2 October 2026. Quote only a figure this page dates. Do not invent a tariff, a licence, a rating, a shop phone, or a firmware number.
Questions
What is program 05 on Deye?
We will not invent it. Read your carton.
Can Deye take any 51.2 V pack?
Only packs the sheet lists. Otherwise you are guessing.
A video numbered the Deye menus. Why will you not confirm the numbers?
Because a number that is not printed on the carton revision in your house would be an invented program number, and this page refuses to invent one. SUN-6K and its siblings have their own labels. We name the jobs those labels point at: battery type, charge current, output priority or work mode, and feed-in. If your carton prints a legend, that legend wins over this website and over the video. Do not load software to force the screen to match a sentence here. Send a photograph of your own screen and the pack sheet if you want a job explained in words rather than in borrowed digits.
Our quote pairs a Deye with Dyness. Can I use the same profile for a different 51.2 V wall?
Only if that other wall is named on the sheet you are holding. A Dyness pairing is a pairing, not a universal pass for every 51.2 V case in the market. Voltage class is not the same thing as a supported profile. If the sheet is silent, you are guessing, and guessing is refused. USE is also refused, so there is no generic lithium bucket to hide in. Cap current at the sheet that does apply, and do not copy a higher figure from a forum because the pack looks large. Photograph the sheet beside the nameplate before you ask the desk to comment.
Can I put a 24 V battery on this Deye hybrid if I only change work mode?
No. This Deye menu is a 48 V class conversation. A 24 V pack is the wrong battery, and work mode does not translate voltage. Do not strap packs into a pretence and do not offer four tubulars as a 2026 hybrid bank. The sheet has to name a pack that belongs on this inverter. Until it does, leave the battery type alone. Feed-in and solar-first are separate jobs and they do not repair a voltage mistake. If a shop sold you the 24 V wall with this hybrid, stop and correct the sale before any menu is treated as the fix.
Who should hold the Deye app login after handover?
The owner holds the owner account from handover day. The installer does not keep the only password, and the family does not share an installer password in a chat. Installer-only fields can change grid and protection behaviour. Those fields are not owner toys and they are not published as a list here. Ask for the owner login in writing on the handover sheet, including the app name the carton actually prints. If a video shows a different app, the carton wins. We will not reset a password by guessing a default, and we will not describe a bypass.
The installer said grid-first and solar-first are the same on a Deye at night. Are they?
No. Solar-first and grid-first are different purposes, and the quote should have picked one. Night behaviour also depends on whether the charger source is allowed to buy units from the utility. If it is, that night fill is a bill, not a gift from the work-mode name. Read the screen you have, photograph it, and compare it with the quote before you blame the roof. Do not hunt a hidden program number to split the difference. Feed-in remains off until the bidirectional meter is in, which is a third setting and not a synonym for work mode.
Is a Growatt MIN supposed to grow a Deye-style battery menu after an update?
No. MIN is not a Deye problem. MIN is Growatt on-grid equipment, and it goes dark in shed because it has no honest hybrid battery menu to reveal. Do not flash it, do not borrow a Deye program number, and do not treat this page as the missing manual. The Growatt letter split lives on the SPH menu page, which refuses an SPH recipe on a MIN. Bring the badge photograph. If the badge says Deye, we can talk about work mode and battery type from the sheet. If it says MIN, stop. Grey firmware will not turn one badge into the other.