Home · shop-house · September 2026

A Pakistani house needs hybrid, not an export farm.

Load-shedding at night, AC in the afternoon, fridge that cannot die. After SRO 251 you size PV to daytime load and buy LFP for the shed — you do not oversize to dump units at Rs 11.

What a house actually runs

The 2026 family stack.

HouseTypical loadPV (645 W plates)InverterBatteryStreet band
Small / 3-marla / shop-houseFans, lights, fridge, TV, router6–7 plates · ~4 kW3.6–6 kW hybrid1 × 5 kWh LFPRs 0.95–1.5 million
Family default / 5–10 marlaAbove + one 1.5-ton AC by day10 plates · 6.45 kW6 kW IP65 hybrid1–2 × 5 kWh LFPRs 1.7–2.5 million
Large / 1 kanal, two ACsTwo 1.5-ton, pump, freezer16 plates · 10.3 kW10 kW hybrid2–3 × 5 kWh LFPRs 2.9–4.4 million

Bands include 14 SWG iron, XLPO, SPD, earthing, labour. Green meter is the DISCO demand notice. Confirm live SKUs.

Backup split

The whole DB does not go on the hybrid.

BACKUP PORT

Must run in shed

LED lights, ceiling fans, fridge, router, maybe one inverter AC if the LFP bank was sized for it. That is the house staying live at 2 a.m.

GRID / NON-BACKUP

Dies with WAPDA — on purpose

Geyser, extra ACs, iron, washing machine, workshop welder. Putting these on backup is how a 6 kW hybrid trips and the fridge dies with them.

Fridge is non-negotiable

A house hybrid without a battery is an on-grid system with extra cost. If the feeder sheds, the fridge is why you bought hybrid.

Night AC is a second cheque

One 1.5-ton for six night hours is ~7 kWh usable — two 5 kWh LFP packs. See single AC before you promise “AC chalay ga”.

Net-billing is optional

Many houses self-consume the afternoon AC and export almost nothing. File the DISCO paper if you have surplus. Do not size the roof for it.

Spec

What we put on a house this month.

Plates

Documented N-type 610–650 W (Hi-MO X10 / Tiger Neo 3.0). 575–590 W TOPCon if the roof is short. No PERC leftover.

Box + bank

IP65 hybrid (Inverex Nitrox / Knox / SolarMax). Default Dyness or Knox 5.12 kWh LFP. Tubular only if the budget is the constraint and nights are fans+lights.

BOS

14 SWG HDG L2, XLPO 6 mm², chemical earth, SPD, labelled isolators. 16 SWG + PVC is a two-summer house.

Home load preset Other use cases If the job is one AC