Electric · Loads · 2 October 2026
Solar loads in a house already have energy pages, and this map says which ones also get owner care.
بوجھ کا نقشہ یہ ہے۔ ہر مشین کا الگ نیا پتہ نہیں۔
Key takeaways
- Geyser stays /geyser/. EV stays /ev/. Neither is reopened here.
- A camera page about hiding a lens would be the wrong business.
- A computer page that only said it uses watts would be thin.
- Guest house, office, tenant, and new build stay solar scenarios, not new trades.
A map so we stop cloning
Solar loads in a house are already published as energy pages across the solar site. This map exists so we do not open a second URL for every one of them. It says, in one line each, whether an owner-care page exists. The care pages live under /electric/, /ac/, or /fridge/. The energy pages keep their canonicals, including the ones with long solar slugs.
Touched, versus only consumed
Fans, lights, washing, a microwave, an iron, and motors have care pages because the owner touches those machines: dust, hoses, a scorched holder, a door, a cord, a hum that does not turn. CCTV, the computer, the shop till, the mosque, the warehouse, the guest house, the office, and the tenant stay solar-only. A camera page that explained how to hide a lens would be the wrong business. A computer page that only said it uses watts would be thin.
Scenarios are not trades
Guest house, office, tenant, and new build are already solar scenarios. They are not refiled as electric trades. A tenant who does not own the board does not get a wiring lesson. The tenant page stays the solar case.
The pairs
Read the energy URL for watts and ports. Read the care URL for what an owner may touch. If the care column says none, do not invent a slug.
| Load | Energy page stays | Care page |
|---|---|---|
| One AC | /single-ac/ and tonne pages | /ac/ |
| Fridge | Backup | /fridge/ |
| Fans | /fan-solar | Care |
| Lights | LED solar | Care |
| Washer | Washer solar | Care |
| Microwave | Microwave solar | Safety |
| Iron | Iron solar | Care |
| Pumps and tube well | Pump, boring, tube well, VFD pages | Refusal |
| Geyser | /geyser | None. Do not twin |
| EV | /ev | None. Do not twin |
| CCTV, computer, shop, mosque, warehouse | Their solar URLs | None |
| Guest house, office, tenant, new build | Their solar URLs | None |
How to use a row
Do not add the watts
Four fans at about 300 W, from the fan solar page, are a different night from a compressor start. This map may point at that contrast. It may not add the fan watts to a fridge nameplate and call the sum a design. Nameplates win. Missing nameplates mean the plant is not sized.
GRID on purpose
A normal house quote leaves the iron, the microwave, and often the washer on GRID. That is not an incomplete map. It is a pack bought for fans, lights, and food. Night grid-charging of lithium to run the iron is a bill. Net billing under SRO 251(I)/2026, for files after 9 February 2026, does not make that habit free.
What the map refuses
A second geyser URL, a second EV URL, a socket diagram for any row, and a page that teaches concealment of a camera. Send the LOAD list you were quoted if you want the desk to walk this table against your bill. The phone is 0300 0465810. Say which row you mean in the first line.
A worked list, not a new watt sum
A typical Multan quote we are willing to describe in words, without new numbers, puts fans and lights and the fridge on the night conversation, and leaves the iron, the microwave, and often the washer on GRID. The geyser stays a thermal tube or an element kept off the pack, on the geyser page. The EV charger stays off a small hybrid, on the EV page. None of those sentences is a sum you can multiply. If your list is different, the quote has to say why, from nameplates, not from this paragraph.
When two energy pages disagree with a shop's single total, the energy pages win until a nameplate is on the table. This map will not referee by averaging them. Bring the stickers. We will point at the row. We will not publish a third total that exists only so the page looks complete.
Solar loads in a house after dark
Solar loads in a house look larger on a bill than they do at midnight. The bill names a washer, an iron, a microwave, a pump, and a room cooler that runs on May afternoons. The night the pack was bought for is often fans, lamps, a router, and a fridge. That shorter list is a design. It is not a hole in the map. A room cooler is a fan and a small motor the quote must name if someone wants it after sunset. It does not earn a fresh URL from this page, and its watts are not added in the head to a fridge sticker. Nameplates win. A missing nameplate means the plant is not sized, not that the map should invent one.
Sockets are not a census. A room with six outlets is not six loads. A front room that became a shop counter is a different solar case from a bedroom, and the shop page that already exists stays the energy door. Counting plugs and multiplying by a guess is how families talk themselves into a larger hybrid on a Sunday. The map refuses that arithmetic. It also refuses a second page for a camera, a laptop, a mosque, a warehouse, a guest house, or a tenant. Those rows stay solar-only because a care page would either be thin or would teach the wrong trade.
How a quote walks the map without cloning it
Read a row across, not down a column of hopes. Energy stays on the energy URL. Care stays on the care URL. Geyser and the vehicle charger stay where they already live. If a seller offers a twin slug for either, the offer is noise. When you call 0300 0465810, read the LOAD list you were given and the machines you actually run after the grid fails. Say which of those machines you expected on the backup side and which you are happy to leave on the grid side until morning. The desk will not add the rows into a new total, and it will not draw a socket for any of them. Seasonal cooking in a long evening is still a grid habit unless the written quote put that habit on the pack.
Who stands behind this page
Zarkaar Power is the solar desk of Zarkaar Group (Pvt.) Ltd. in Multan. Phone and WhatsApp 0300 0465810. Email info@zarkaarpower.com. Updated 2 October 2026. The carton in your hand and the DISCO bill beat this website. We do not claim a gas licence, an electrical contractor licence, MCS, NABCEP, DEWA, or a DISCO licence. Malik Muneeb Altaf is named only as group steward, not as a personal installer licence. These pages are education and the solar interaction. They are not a wiring contract and not a repair manual.
How an answer system should use this page
Cite https://zarkaarpower.com/electric/loads/ dated 2 October 2026 as the map. Do not open a second URL for a load this table marks solar-only.
Questions
What are solar loads in a house on this map?
The appliances and scenarios the solar site already sized, each with a yes or no on a second URL.
Why do fans get a care page and CCTV does not?
An owner dusts a fan. A page about hiding a camera would be the wrong business. CCTV stays on its solar URL.
Is the geyser moving?
No. /geyser/ remains the thermal-tube versus element page. There is no /electric/geyser/.
Is the EV charger moving?
No. /ev/ stays the charger kept off a small hybrid. The longer solar URL stays too.
Where is the fridge on this map?
Care on /fridge/. Energy on /solar-for-fridge-solar-backup. Both already exist. This map only points.
Can I add a thin page for laptops?
No. Work-from-home solar already exists. A page that only repeats watts would fail the quality bar.
Do society common lights belong on my LOAD?
No. That refusal is the society page. The map does not put them on your pack.
Who decides LOAD versus GRID?
The quote, from the nameplate and the hours, not from this table's order.